Covidien > Nellcor Compatible Disposable SpO2 Sensor - Pediatric (10-50Kg) Box of 24
Covidien > Nellcor Compatible Disposable SpO2 Sensor - MAX-P
Price:
$264
OEM Part Number Cross References:
Manufacturer | OEM Part # |
---|---|
Covidien > Nellcor | MAX-P, MAX-P-I |
Draeger | MX50066 |
GE Healthcare > Marquette | 70124022 |
Mindray > Datascope | 0010-10-12203 |
Sage | DP062X-09M |
Stryker > Medtronic > Physio Control | 11996-000116 |
Compatibility:
Manufacturer | Model |
---|---|
Baxter | Explorer, Monarch |
Biolight | M9500, Q Series, Q3, Q5, Q7 |
Biosys | BPM-200, SENTRY |
CAS Med | 511 |
Covidien > Nellcor | N-10, N-180, N-190, N-20, N-30, N-560, N-600, N-600x, N-65, N-85, NPB-190, NPB-195, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, PM100N, PM10N, Sensors that have Nellcor OxiMax Technology and 9 pins |
Criticare | 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
DRE | ASM 5000, Waveline, Waveline Plus |
Digicare | LW600 |
Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Narkomed 6400 |
Fukuda Denshi | Dynascope DS-7100, LX-7230N |
GE Healthcare > Critikon > Dinamap | B105, B125, Carescape B650, Carescape V100, Compact DINAMAP MPS, E-NSAT, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro Series V2, ProCare 200, ProCare 400, ProCare Ausculatory 400 |
GE Healthcare > Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, PDM Module, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500 |
Goldway | Vet 420A, Vet 600A |
Medtronic > Covidien | Capnostream 35 (PM35MN) |
Midmark > Cardell | 9403, 9405, 9500 Series, 9500HD, MAX-12 Duo HD |
Mindray > Datascope | Accutorr Plus, BeneView T1, BeneVision N1, DPM5, DPM6, DPM7, Duo, Expert, Passport, Passport 12, Passport 2, Passport 8, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V-Series, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, ePM 10M, ePM 12M, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC Series, iPM-9800 |
Mortara | Surveyor S12/S19 |
Omron > Colin | BP-S510, T105NXM |
Philips | FM20, FM30, Heartstream XL, IntelliVue, IntelliVue FAST-SpO2, IntelliVue MP2, IntelliVue MP70, IntelliVue MX450, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3 |
Smiths Medical > BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Autocorr, Mini Torr, Mini Torr Plus |
Spacelabs | Ultraview SL, Ultraview SL 2700 |
Stryker > Medtronic > Physio Control | Lifepak 12, Lifepak 15 |
Welch Allyn | 1500, 42NT0-E1 LXi, 52N Series, 53N Series, 64N Series, 65N Series, 67N Series, 68N Series, 71WT-B Connex Spot, 73C Series, 74C Series, 75CE-B, 75CT-B, 75CX-B, 901058, All, Atlas (Nellcor SpO2), Atlas 6200 Series, Connex 6000 series, Encore 202EL, Propaq 244, Propaq CS, Propaq LT, Spot Vital Signs 42MOB, Spot Vital Signs 42NOB, Spot Vital Signs 42NTB-E1 |
Zoll | E Series, M Series, R Series |
Technical Specifications:
Cable Color | White |
---|---|
Cable Diameter | 3.2 mm |
Cable Material | PVC Jacket |
Category | SpO2 |
Certifications | FDA, CE, ISO 80601-2-61:2011, ISO10993-1, 5, 10:2003E, TUV, RoHS Compliant |
Connector Distal | Male 9-Pin D-Sub Purple Connector, Dual Keyed |
Connector Proximal | Pediatric Adhesive |
Latex-free | Yes |
Packaging Type | Box |
Packaging Unit | 24 |
Patient Size | Pediatric (10-50Kg) |
SpO2 Technology | Nellcor OxiMax |
Sterile | No |
Total Cable Length | 1.5 ft |
Warranty | 0 months |
Weight | 1.8lb |