Masimo Compatible Disposable SpO2 Sensor - Adult (>40Kg) Box of 20
Masimo Compatible Disposable SpO2 Sensor - 1859 LNCS Adtx
Price:
$198
OEM Part Number Cross References:
Manufacturer | OEM Part # |
---|---|
Draeger | MP00790 |
GE Healthcare > Marquette | 2027253-001 |
Masimo | 1859 LNCS Adtx (18"), 2317 (LNCS Adtx-3) (3 ft) |
Mindray > Datascope | 0600-00-0121, 520A-30-64101 |
Philips | 989803148231 |
Spacelabs | 690-0252-00 (18") |
Stryker > Medtronic > Physio Control | 11171-000019 |
Zoll | 8000-0320 |
Compatibility:
Manufacturer | Model |
---|---|
Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
Datex Ohmeda | Giraffe Infant Warmer, S/5 |
Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400 |
GE Healthcare > Corometrics | 128, 250, 250cx, TRAM 450SL |
GE Healthcare > Critikon > Dinamap | Carescape B650, Carescape B850, Carescape V100, Carescape V100 with Masimo technology, Dinamap ProCare with Masimo Pro 1000, Pro 300V2, ProCare 300, ProCare Ausculatory 400, ProSeries V2, V300 |
GE Healthcare > Marquette | 8000 e Eagle 1000, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle, PDM Module, Procare B40, SOLAR, Smk SMV, Solar 7000, Solar 8000, Solar 8000M, Solar Series, TRAM Modular, Tram 451, i/9500, i/9500 (Tram 451N5/851N5), x50SL Series |
Invivo | Escort II OPT30 Prism, T8 |
Masimo | All, Pronto-7, Rad-5, Rad-57, Rad-8, Rad-87, Radical-7 |
Mennen | Horizon XVu |
Mindray > Datascope | Accutor V, Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision TMS60, BeneVision TMS80, Beneheart D6, DPM4, DPM6, DPM7, Duo, EPM4, MEC 12, MPM, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Passport 12, Passport 2, Passport 2LT, Passport 8, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V12, V21, VS 8, VS 800, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, cPM 12, cPM 8, ePM 10M, ePM 12M, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC Series, iPM-9800 |
Penlon InterMed | All |
Philips | Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3, VM4 |
Respironics | Alice 5 |
Stryker > Medtronic > Physio Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
Welch Allyn | 1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, 64H Series, 64M Series, 65H Series, 65M Series, 67M Series, 68M Series, Propaq CS, Propaq LT, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs lXi |
Zoll | E Series, M Series, R Series, X Series |
Technical Specifications:
Cable Color | White |
---|---|
Cable Diameter | 3.2 mm |
Cable Material | PVC Jacket |
Category | SpO2 |
Certifications | FDA, CE, ISO 80601-2-61:2011, ISO10993-1, 5, 10:2003E, TUV, RoHS Compliant |
Connector Distal | Male, 9-Pin D-Sub Connector, Triple Keyed |
Connector Proximal | Adult Masimo LNCS Adtx |
Latex-free | Yes |
Packaging Type | Box |
Packaging Unit | 20 |
Patient Size | Adult (>40Kg) |
SpO2 Technology | Masimo |
Sterile | No |
Total Cable Length | 1.5 ft |
Warranty | 0 months |
Weight | 1.8lb |