Philips Compatible ECG Leadwire - 5 Leads Pinch/Grabber
Philips Compatible ECG Leadwire - M1968A
Price:
$66
OEM Part Number Cross References:
Manufacturer | OEM Part # |
---|---|
3M | YMRLW5P51 |
AMC | LW-3090SMX/5A (Mixed Length), LW-3090S51/5A (51 inch) |
Curbell | LDW-05BK-MXAS-0000 (Mixed Length), LDW-05BK-29AS-0000 (29 inch), LDW-05BK-51AS-0000 (51 inch), RLW-05BK-39AS-0000 (39 inch), 19886 (39 inch), 9014 (39 inch), RLW-05BK-MXAS-0000 (Mixed Length), 9018 (Mixed Length), 19887 (Mixed Length) |
Philips | M1968A, 989803125841, M1973A (Orange) |
Sage | L01-05-MP |
Compatibility:
Manufacturer | Model |
---|---|
Bexen Cardio | Reanibex 700 |
Biolight | M7000, M8500, M9500, Q Series |
Invivo | 101, 360SL, 450SL, 521A, Escort 100, Escort 101, Escort 102, Escort 200, Escort 300, PortaPak 1000, PortaPak 80, PortaPak 90, Prism |
Ivy Biomedical | 101, 7800, Cardiac Trigger Monitor 3150 |
Newtech | NT3A |
Nihon Kohden | BSM-8301A, BSM-8302A, BSM-8500A, BSM-8502A, NT3B, OEC-6102A (s/n>20156), OEC-6105A (s/n>20226), OEC-7102A, OEC-8108A, TEC-5200A (s/n>20421), TEC-7100A, TEC-7200A, TEC-7300A |
PaceTech | MiniMax 4000CL, Minipack 300, Minipack 3000, Minipack 3100, Vitalmax 2100, Vitalmax 2200, Vitalmax 4000, Vitalmax 4000 Modular, Vitalmax 4000CL, Vitalmax 4100, Vitalmax 4100CL, Vitalmax 800 Plus |
Philips | 43100A, 43110A, 43120A, 78352C, 78354C, 78834C, 862474 C3, 867036, Affiniti 30, Affiniti 50, Affiniti 70, Affiniti CVx, Agilent, Agilent 50XM, CX50, EPIQ, EPIQ 7, Envisor, HD15, HeartStart MRx, Heartstart, IE33, IntelliVue, IntelliVue MX500, IntelliVue MX750, IntelliVue MX800, IntelliVue MX850, M1001A, M1002A, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M2, M2475B, M2601A, M3, M3000A, M3001A, M4, M4735A, MMS X2, MP 20, MP 30, MP 50, MP 60, MP 70, SureSigns VM6, SureSigns VM8, V24E, VM4, VM6, VM8, Viridia, М3046А |
Solaris | NT3C, NT3E, NT3F |
Spacelabs | 400, 500, 600, 900, 90300, 90303B, 90308, 90408, 90425, 90428, 90431, 90432, 90470, 90600, 90700, 90701, 90721, 90724, PC Bedside, PCMS, TEK-208, TEK-408, TEK-413, TEK-414, TEK-511, TEK-512, TEK-514, TEK-5214045 |
Stryker > Medtronic > Physio Control | Lifepak 6, VSM-1ESF |
Welch Allyn | 242, Propaq Encore 206EL |
Technical Specifications:
Category | ECG |
---|---|
Certifications | FDA, CE, ISO10993-1, 5, 10:2003E, TUV, RoHS Compliant |
Connector Distal | Din Style, Molded Leads |
Connector Proximal | Pinch/Grabber |
Latex-free | Yes |
Lead Cable Color | Gray |
Lead Cable Diameter | 2.6 mm |
Lead Cable Length Limb | 3 ft |
Lead Cable Length V | 3 ft |
Lead Cable Material | TPU Jacket |
Lead Color Coding | AHA |
Lead Number | 5 |
Packaging Type | Bag |
Packaging Unit | 1 |
Patient Size | Adult/Pediatric |
Resistance | No |
Shielding | Yes |
Sterile | No |
Warranty | 6 months |
Weight | 0.3lb |